DOPO2 All-in-1 Handheld Optical Gas and Dissolved Oxygen Sensor,High Performance
$ 844.8
- Description
- Size Guide
Description
Dissolved oxygen sensor with an embedded EOM (Electro Optic Module) and embedded temperature and pressure sensors for monitoring of oxygen in both gaseous and aqueous environments. The outer diameter of its stainless-steel probe is 5/8" (15.875 mm) and it is 10" (25.4 cm) long.This fluorescence quenching based fiber optics sensor is hydrocarbon compatible and can be used to monitor dissolved oxygen in Organic solvents, Alcohols, fuels, oils,…. The sensor patch (HCR series) held in place by a screw-on cap with a response time less than 1 Sec. The sensor cap can be replaced with another cap or a fiber optic probe.
The DOPO2 connects to a PC via USB connection and can be configured with single-channel LED excitation and detection, and modulation frequencies up to 31.2 kHz. The on-board pressure transducer and thermistor measure atmospheric pressure and sample temperature.
Temperature data is used for sensor temperature compensation
. Sensor cap is rated up to 55 bar pressures.
DOPO2 Viewer Software and standard factory calibration is included.
DOPO2 (EOM) Specifications:
Dimensions:
OD: 16 mm
L: 260 mm
Weight:
179 g
Principle:
Photoluminescence quenching using organo-metallic compounds in sol gel host
Parameters measured:
Gaseous oxygen partial pressure, dissolved oxygen concentration, temperature, pressure (via onboard pressure transducer)
Compatibility:
Hydrocarbons, fuels, organic solvents and oils
Control Software:
Windows 7, 8, 10 control software with data logging capability; controls include: modulation frequency, data rate, signal averaging, LED gain, LED intensity
Sampling Rate:
Acquires data samples every 0.1 second (10 Hz) (Software can be configured to different sample rates)
NOTE: This is not the response speed of the probe, just the rate at which the probe is digitally sampled
Pressure Measurement:
On-board pressure transducer monitors atmospheric pressure
4-20 mA Output Accuracy (at 25˚C):
+/- 0.1%
Electronics Operating Temperature Range:
0 °C
to +55 °C
External Power Supply Voltage Range:
4.75 to 5.25V
Power Consumption:
100 mA
Communications:
USB
HCR formulation (sol gel) Specifications
Response rate
T90 <1 second
Dynamic range in gas
0-100% O2/0-760 mmHg O2
Dynamic range in water (DO)
0-40 ppm (wt)
Dynamic range in other liquids
0-oxygen saturation level
Resolution in gas
0.05% O2 / 0.4 mmHg
Resolution in water (DO)
0.02 ppm (wt) / 20 ppb (wt)
Resolution in other liquids
0.05% of oxygen saturation level
Accuracy
5% of reading
Lowest detectable level (gas)
0.05 % O2 / 0.4 mmHg
Lowest detectable level (water)
0.02 ppm (wt) / 20 ppb (wt)
Lowest detectable level in other liquids
0.05% of oxygen saturation level
Sensor drift
0.0001 O2% per hour
Operating temperature
-50 to + 120 C
Recommended replacement for sensor cap
1 year